1,743 research outputs found

    Improving the clinical value and utility of CGM systems: issues and recommendations : a joint statement of the European Association for the Study of Diabetes and the American Diabetes Association Diabetes Technology Working Group

    Get PDF
    The first systems for continuous glucose monitoring (CGM) became available over 15 years ago. Many then believed CGM would revolutionise the use of intensive insulin therapy in diabetes; however, progress towards that vision has been gradual. Although increasing, the proportion of individuals using CGM rather than conventional systems for self-monitoring of blood glucose on a daily basis is still low in most parts of the world. Barriers to uptake include cost, measurement reliability (particularly with earlier-generation systems), human factors issues, lack of a standardised format for displaying results and uncertainty on how best to use CGM data to make therapeutic decisions. This scientific statement makes recommendations for systemic improvements in clinical use and regulatory (pre- and postmarketing) handling of CGM devices. The aim is to improve safety and efficacy in order to support the advancement of the technology in achieving its potential to improve quality of life and health outcomes for more people with diabetes

    Improving the clinical value and utility of CGM systems: issues and recommendations: a joint statement of the European Association for the Study of Diabetes and the American Diabetes Association Diabetes Technology Working Group

    Get PDF
    The first systems for continuous glucose monitoring (CGM) became available over 15 years ago. Many then believed CGM would revolutionize the use of intensive insulin therapy in diabetes; however, progress toward that vision has been gradual. Although increasing, the proportion of individuals using CGM rather than conventional systems for self-monitoring of blood glucose on a daily basis is still low in most parts of the world. Barriers to uptake include cost, measurement reliability (particularly with earlier-generation systems), human factors issues, lack of a standardized format for displaying results, and uncertainty on how best to use CGM data to make therapeutic decisions. This Scientific Statement makes recommendations for systemic improvements in clinical use and regulatory (pre- and postmarketing) handling of CGM devices. The aim is to improve safety and efficacy in order to support the advancement of the technology in achieving its potential to improve quality of life and health outcomes for more people with diabetes

    Diabetes Digital App Technology: Benefits, Challenges, and Recommendations. A Consensus Report by the European Association for the Study of Diabetes (EASD) and the American Diabetes Association (ADA) Diabetes Technology Working Group

    Get PDF
    Digital health technology, especially digital and health applications ("apps"), have been developing rapidly to help people manage their diabetes. Numerous health-related apps provided on smartphones and other wireless devices are available to support people with diabetes who need to adopt either lifestyle interventions or medication adjustments in response to glucose-monitoring data. However, regulations and guidelines have not caught up with the burgeoning field to standardize how mobile health apps are reviewed and monitored for patient safety and clinical validity. The available evidence on the safety and effectiveness of mobile health apps, especially for diabetes, remains limited. The European Association for the Study of Diabetes (EASD) and the American Diabetes Association (ADA) have therefore conducted a joint review of the current landscape of available diabetes digital health technology (only stand-alone diabetes apps, as opposed to those that are integral to a regulated medical device, such as insulin pumps, continuous glucose monitoring systems, and automated insulin delivery systems) and practices of regulatory authorities and organizations. We found that, across the U.S. and Europe, mobile apps intended to manage health and wellness are largely unregulated unless they meet the definition of medical devices for therapeutic and/or diagnostic purposes. International organizations, including the International Medical Device Regulators Forum and the World Health Organization, have made strides in classifying different types of digital health technology and integrating digital health technology into the field of medical devices. As the diabetes digital health field continues to develop and become more fully integrated into everyday life, we wish to ensure that it is based on the best evidence for safety and efficacy. As a result, we bring to light several issues that the diabetes community, including regulatory authorities, policy makers, professional organizations, researchers, people with diabetes, and health care professionals, needs to address to ensure that diabetes health technology can meet its full potential. These issues range from inadequate evidence on app accuracy and clinical validity to lack of training provision, poor interoperability and standardization, and insufficient data security. We conclude with a series of recommended actions to resolve some of these shortcomings

    Combining Glucose Monitoring and Insulin Infusion in an Integrated Device: A Narrative Review of Challenges and Proposed Solutions.

    Get PDF
    The introduction of automated insulin delivery (AID) systems has enabled increasing numbers of individuals with type 1 diabetes (T1D) to improve their glycemic control largely. However, use of AID systems is limited due to their complexity and costs associated. The user must wear both a continuously monitoring glucose system and an insulin infusion pump. The glucose sensor and the insulin catheter must be inserted at two different body sites using different insertion devices. In addition, the user must pair and manage the different systems. These communicate with the AID software implemented on the pump or on a third device such as a dedicated display device or smart phone application. These components might be developed and commercialized by different manufacturers, which in turn can cause difficulties for patients seeking technical support. A possible solution to these challenges would be to integrate the glucose sensor and insulin catheter into a single device. This would allow the glucose sensor and insulin catheter to be inserted simultaneously, eliminating the need for pairing, and simplifying system management. In recent years, different technologies have been developed and evaluated in clinical investigations that combine the glucose sensor and the insulin catheter in one platform. The consistent finding of all these studies is that integration has no adverse effect on insulin infusion and glucose measurements provided that certain conditions are met. In this review, we discuss the perceived challenges of such an approach and discuss possible solutions that have been proposed

    Impact of diabetic nephropathy on pharmacodynamic and pharmacokinetic properties of insulin in type 1 diabetic patients

    Get PDF
    WSTĘP. Celem pracy jest ilościowa ocena parametrów farmakodynamicznych i farmakokinetycznych krótkodziałającej insuliny ludzkiej i insuliny lispro u chorych na cukrzycę typu 1 z i/lub bez jawnej nefropatii cukrzycowej. MATERIAŁ I METODY. Badanie przeprowadzone metodą podwójnie ślepej próby miało charakter krzyżowy. Stosując technikę klamry euglikemicznej (5 mmol/l), oceniano odpowiedź metaboliczną na podskórne wstrzyknięcia insuliny krótkodziałającej i lispro (0,2 j./kg) u 12 chorych z cukrzycą typu 1 i jawną nefropatią cukrzycową (białkomocz > 500 mg/24 h i/lub stężenie kreatyniny w surowicy > 1,5 mg/dl, grupa NP) oraz u 12 chorych na cukrzycę typu 1 z prawidłową funkcją nerek, stanowiących grupę kontrolną (grupa DC). WYNIKI. Szczytowe stężenie wolnej insuliny w osoczu w przypadku lispro (359 [NP] vs. 254 pmol/l [DC]) było wyższe, a czas do osiągnięcia maksymalnego stężenia insuliny (85 [NP] vs. 99 min [DC]) był krótszy niż w przypadku ludzkiej insuliny krótkodziałającej (213 [NP] vs. 144 pmol/l [DC]; 118 [NP] vs. 153 min [DC]) w obu grupach chorych. Podsumowując, stężenia ludzkiej insuliny krótkodziałającej i lispro były wyższe u chorych z jawną nefropatią niż w grupie kontrolnej. Czas do uzyskania maksymalnego efektu metabolicznego był krótszy w przypadku insuliny lispro niż w przypadku insuliny ludzkiej w obu grupach chorych (102 vs. 191 min [NP]; 105 vs. 172 min [DC]). Całkowity efekt metaboliczny insuliny krótkodziałającej w przeciwieństwie do insuliny lispro był mniejszy u chorych z nefropatią cukrzycową niż z grupie kontrolnej (odpowiednio 967 vs. 1510 mg/kg). WNIOSKI. Chociaż stwierdzono wyższe stężenia insuliny u chorych z nefropatią cukrzycową, odpowiedź metaboliczna na ludzką insulinę krótkodziałającą pozostaje zmniejszona. Insulina lispro zachowuje swoją charakterystyczną farkmakokinetykę i farmakodynamikę u chorych z jawną nefropatią cukrzycową.INTRODUCTION. To quantify pharmacokinetic and pharmacodynamic properties of regular insulin and insulin lispro in type 1 diabetic patients with and without overt diabetic nephropathy. MATERIAL AND METHODS. In this double-blind, two- -way cross-over, euglycemic (5 mmol/l) glucose clamp study, we investigated the metabolic response to subcutaneous injections of regular insulin and insulin lispro (0.2 U/kg) in 12 type 1 diabetic patients with overt diabetic nephropathy (proteinuria > 500 mg/24 h and/or serum creatinine > 1.5 mg/dl; NP group) and in a control group of 12 type 1 diabetic patients with normal renal function (DC group). RESULTS. Peak plasma free insulin levels with insulin lispro (359 [NP] vs. 254 pmol/l [DC]) were higher and time to maximal insulin concentrations (85 [NP] vs. 99 min [DC]) shorter than with regular insulin (213 [NP] vs. 144 pmol/l [DC]; 118 [NP] vs. 153 min [DC]) in both patient groups. Overall insulin levels for regular insulin and for insulin lispro were higher in patients with overt diabetic nephropathy compared with control patients. Time to maximal metabolic effect was shorter with insulin lispro than with regular insulin in both patient groups (102 vs. 191 min [NP]; 105 vs. 172 min [DC]). The overall metabolic effect of regular insulin but not of insulin lispro was lower in patients with diabetic nephropathy than in diabetic control patients (967 vs. 1,510 mg/kg, respectively). CONCLUSIONS. Although insulin levels are higher in patients with overt diabetic nephropathy, the metabolic response to regular insulin is reduced. Insulin lispro maintains its characteristic pharmacokinetic and pharmacodynamic properties in patients with overt diabetic nephropathy

    Improved Preservation of Residual Beta Cell Function by Atorvastatin in Patients with Recent Onset Type 1 Diabetes and High CRP Levels (DIATOR Trial)

    Get PDF
    A recent randomized placebo-controlled trial of the effect of atorvastatin treatment on the progression of newly diagnosed type 1 diabetes suggested a slower decline of residual beta cell function with statin treatment. Aim of this secondary analysis was to identify patient subgroups which differ in the decline of beta cell function during treatment with atorvastatin.The randomized placebo-controlled Diabetes and Atorvastatin (DIATOR) Trial included 89 patients with newly diagnosed type 1 diabetes and detectable islet autoantibodies (mean age 30 years, 40% females), in 12 centers in Germany. Patients received placebo or 80 mg/d atorvastatin for 18 months. As primary outcome stimulated serum C-peptide levels were determined 90 min after a standardized liquid mixed meal. For this secondary analysis patients were stratified by single baseline characteristics which were considered to possibly be modified by atorvastatin treatment. Subgroups defined by age, sex or by baseline metabolic parameters like body mass index (BMI), total serum cholesterol or fasting C-peptide did not differ in C-peptide outcome after atorvastatin treatment. However, the subgroup defined by high (above median) baseline C-reactive protein (CRP) concentrations exhibited higher stimulated C-peptide secretion after statin treatment (p = 0.044). Individual baseline CRP levels correlated with C-peptide outcome in the statin group (r(2) = 0.3079, p<0.004). The subgroup with baseline CRP concentrations above median differed from the corresponding subgroup with lower CRP levels by higher median values of BMI, IL-6, IL-1RA, sICAM-1 and E-selectin.Atorvastatin treatment may be effective in slowing the decline of beta cell function in a patient subgroup defined by above median levels of CRP and other inflammation associated immune mediators.ClinicalTrials.gov NCT00974740

    Evaluating Glucose Control With a Novel Composite Continuous Glucose Monitoring Index.

    Get PDF
    OBJECTIVE: The objective was to describe a novel composite continuous glucose monitoring index (COGI) and to evaluate its utility, in adults with type 1 diabetes, during hybrid closed-loop (HCL) therapy and multiple daily injections (MDI) therapy combined with real-time continuous glucose monitoring (CGM). METHODS: COGI consists of three key components of glucose control as assessed by CGM: Time in range (TIR), time below range (TBR), and glucose variability (GV) (weighted by 50%, 35% and 15%). COGI ranges from 0 to 100, where 1% increase of time 7.5-10%, had significantly higher COGI during 12 weeks of HCL compared to sensor-augmented pump therapy, mean (SD), 60.3 (8.6) versus 69.5 (6.9), P 7.5% to 9.9%, use of real-time CGM led to improved COGI, 49.8 (14.2) versus 58.2 (9.1), P < .0001. In MDI users with impaired awareness of hypoglycemia, use of real-time CGM led to improved COGI, 53.4 (12.2) versus 66.7 (11.1), P < .001. CONCLUSIONS: COGI summarizes three key aspects of CGM data into a concise metric that could be utilized to evaluate the quality of glucose control and to demonstrate the incremental benefit of a wide range of treatment modalities

    Assessing the effectiveness of 3 months day and night home closed-loop insulin delivery in adults with suboptimally controlled type 1 diabetes: a randomised crossover study protocol.

    Get PDF
    INTRODUCTION: Despite therapeutic advances, many people with type 1 diabetes are still unable to achieve optimal glycaemic control, limited by the occurrence of hypoglycaemia. The objective of the present study is to determine the effectiveness of day and night home closed-loop over the medium term compared with sensor-augmented pump therapy in adults with type 1 diabetes and suboptimal glycaemic control. METHODS AND ANALYSIS: The study will adopt an open label, three-centre, multinational, randomised, two-period crossover study design comparing automated closed-loop glucose control with sensor augmented insulin pump therapy. The study will aim for 30 completed participants. Eligible participants will be adults (≥18 years) with type 1 diabetes treated with insulin pump therapy and suboptimal glycaemic control (glycated haemoglobin (HbA1c)≥7.5% (58 mmol/mmol) and ≤10% (86 mmol/mmol)). Following a 4-week optimisation period, participants will undergo a 3-month use of automated closed-loop insulin delivery and sensor-augmented pump therapy, with a 4-6 week washout period in between. The order of the interventions will be random. All analysis will be conducted on an intention to treat basis. The primary outcome is the time spent in the target glucose range from 3.9 to 10.0 mmol/L based on continuous glucose monitoring levels during the 3 months free living phase. Secondary outcomes include HbA1c changes; mean glucose and time spent above and below target glucose levels. Further, participants will be invited at baseline, midpoint and study end to participate in semistructured interviews and complete questionnaires to explore usability and acceptance of the technology, impact on quality of life and fear of hypoglycaemia. ETHICS AND DISSEMINATION: Ethical approval has been obtained at all sites. Before screening, all participants will be provided with oral and written information about the trial. The study will be disseminated by peer-review publications and conference presentations. TRIAL REGISTRATION NUMBER: NCT01961622 (ClinicalTrials.gov)

    Day and night home closed-loop insulin delivery in adults with type 1 diabetes: three-center randomized crossover study.

    Get PDF
    OBJECTIVE: To evaluate the feasibility of day and night closed-loop insulin delivery in adults with type 1 diabetes under free-living conditions. RESEARCH DESIGN AND METHODS: Seventeen adults with type 1 diabetes on insulin pump therapy (means ± SD age 34 ± 9 years, HbA1c 7.6 ± 0.8%, and duration of diabetes 19 ± 9 years) participated in an open-label multinational three-center crossover study. In a random order, participants underwent two 8-day periods (first day at the clinical research facility followed by 7 days at home) of sensor-augmented insulin pump therapy (SAP) or automated closed-loop insulin delivery. The primary end point was the time when sensor glucose was in target range between 3.9 and 10.0 mmol/L during the 7-day home phase. RESULTS: During the home phase, the percentage of time when glucose was in target range was significantly higher during closed-loop compared with SAP (median 75% [interquartile range 61-79] vs. 62% [53-70], P = 0.005). Mean glucose (8.1 vs. 8.8 mmol/L, P = 0.027) and time spent above target (P = 0.013) were lower during closed loop, while time spent below target was comparable (P = 0.339). Increased time in target was observed during both daytime (P = 0.017) and nighttime (P = 0.013). CONCLUSIONS: Compared with SAP, 1 week of closed-loop insulin delivery at home reduces mean glucose and increases time in target without increasing the risk of hypoglycemia in adults with relatively well-controlled type 1 diabetes.This is the author accepted manuscript. The final version can be found published here: http://care.diabetesjournals.org/content/37/7/1931.abstract
    corecore